HOME
Hot-selling products
Product Catalog
Product video
Catalogue PDF
BRT frequency treatment equipment
Real feedback from customers
Our client
About Us
Contact Us

Product Catalog 

2015 new Blood testing equipment Professional Microcirculation Microscope

  • 2015 new Blood testing equipment Professional Microcirculation Microscope
  • 2015 new Blood testing equipment Professional Microcirculation Microscope
  • 2015 new Blood testing equipment Professional Microcirculation Microscope
  • 2015 new Blood testing equipment Professional Microcirculation Microscope
  • 2015 new Blood testing equipment Professional Microcirculation Microscope
  • 2015 new Blood testing equipment Professional Microcirculation Microscope
  • 2015 new Blood testing equipment Professional Microcirculation Microscope
  • 2015 new Blood testing equipment Professional Microcirculation Microscope
  • 2015 new Blood testing equipment Professional Microcirculation Microscope
Model No.︰GY-880
Brand Name︰SSCH
Country of Origin︰China
Unit Price︰US $ 499 / pc
Minimum Order︰1 pc
Share on:

 Total 15 Related Items 
Prev12345Next

Product Description

      

2015 new Blood testing equipment Professional Microcirculation Microscope

 

 

Capillary Microcirculation Scope / microcirculation microscope

 

 

What's micro circulation ?

 

The micro circulation is by blood, the lymph and tissue fluid

flowing which directly participates in the organization, the cell

matter, the energy, the information transmission . May directly

observe the blood flows in the thin artery, the blood capillary,

and the thin vein  through the micro circulation microscope , but

if it does not do the special handling is that cannot see clearly

the lymph and tissue fluid mobile, therefore, on clinical usually

thought the micro circulation  refers to the blood micro

circulation in the blood capillary .

 

 

 

Distributed pattern for  finger nail fold blood capillary 

 

 

 

 

 

Distributed pattern for  finger nail fold blood capillary

 

 

The observation for nail fold micro circulation is mainly from

three aspects ,including the shape, the fluid state and the blood

vessel ansa perimeter.

 

 

 

     (Clear)                                                   (Is not clear)                                          (Fuzzy)

 

Normal state: Nail fold blood capillary arrangement neat,

distribution even, the blood vessel ansa is clearly discernible.

 

 

Abnormal state: Arrangement disorder, blood vessel ansa fuzzy

, is possible to because of the oxygen deficit, the blood stream

to be impeded, the Asian health and so on causes.

 

 

 

Shape of blood vessel ansa :

 

(1) Normal shape likes the hair clip , exceptionally for

overlapping and abnormal, the overlapping proportion number

should not surpass 30%, the abnormal should not surpass 10%

 

 

(2) abnormal blood vessel:

 

Explained: 1st, the  blood vessel of heart and brain disease, the

diabetes, the desmosis and so on, with contract whole body

disease or the partial fungus infection and flesh wound and

other  organization disease  is easy to appear the blood vessel

to be abnormal

 

2nd, when arteriosclerosis,  diabetes with serious abnormal ,

 

and the proportion excessive highly.

 

3rd, collagen disease, Reynold sickness, neurosis, the variation

 

of blood vessel increases.

 

 

 

Blood vessel ansa’s periphery

 

After has carried on the shape and the fluid state observation

, but also should carry on the observation to the periphery

condition:

 

1.Seeps out:  refers to, in the blood vessel, appears the

 

phenomenon for the blood plasma ingredient excessively

permeability blood pipe wall and the accumulation in blood

capillary’s periphery  , is one of common micro circulation

changes. Characteristic: The blood vessel ansa periphery gap

expands, and bright; The blood vessel ansa’s image is fuzzy, the

 

length reduces.

 

2.Hemorrhage: phenomenon for the red blood cell leaves to the

blood vessel outside .

 

Should distinguish the hemorrhage which the flesh wound or

other non- pathogenesis factor creates, if the leakage 

hemorrhage, the main reason is blood capillary wall damage,

causes the permeability hyperfunction and the blood flow

changes and so on .


Blood microcirculation

1. Model XW880(7inch/8inch color LCD)


2. For health care&beautiful industry


3. CE certificate, Nation patent


4. Independent research and development ability


5. nailfold microcirculation microscope is a noninvasive health

diagnostic device

 


Features:

 

1.in 5 seconds can be observed in the microvascular circulation,

simple operation and fast;


2.the microscopic image is stable, clear, do not shake;


3.400 times the microcirculation of a dedicated high-resolution

lens of the microscope;
4.handheld ultra-light design, so that the observation of more

mobility;
5.with micro-focus wheel, free to adjust the focus length, the

use of more convenience


6.lens built-in LED cold light source, accurate projection

illumination on an object;


7.using non-invasive way, to observe the microcirculation of

human body in time;


8.observing the microcirculation for any part of human body.

 

 

 

How to use

 

 1, Put a little cedar oil daub on the nails and cuticles need to be test

 

 2, Put the finger in the slot, and then adjust the focal length and position

 

3, Looking for blood vessel and to observe

 

Inside and outside packaging

 

 

 

 

 

Packing︰1pcs/box 5pca/carton
Lead Time︰3-5Days
Standards Certificate︰CE
Product Image










Related Products
Portable video microscope capillary microcirculation microscope XW880
Portable video microscope capillary microcirculation microscope XW880
US $ 499
Blood vessel microscope blood microcirculation test Analyzer
Blood vessel microscope blood microcirculation test Analyzer
US $ 499
Nailfold Capillary Microscopy Color Microcirculation Microscope video microcircu
Nailfold Capillary Microscopy Color Microcirculation Microscope video microcircu
US $ 499
color nailfold Microcirculation equipment capillary microscope
color nailfold Microcirculation equipment capillary microscope
US $ 499




HOME  |  Hot-selling products  |  Product Catalog  |  Product video  |  Catalogue PDF  |  BRT frequency treatment equipment  |  Real feedback from customers  |  Our client  |  About Us  |  Contact Us  |  Sitemap  |  Mobile Version
  English     简体版     繁體版

Powered by DIYTrade.com  Build your FREE website !

HomeContact UsSitemap